Cathodic Protection Monitoring and Retrofit Design Training Course
Read survey, depletion and interference evidence on ageing pipelines, tanks and platforms, then size retrofits and set monitoring that keeps steel protected.
This 1-week course has 25 dates from November 2026 to October 2027 in 24 cities and live online. The next session runs 23 – 27 November 2026 in Vienna. Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online.
See dates and book Download brochure (PDF) Training for your team
- Duration
- 1 Week
- Next start
- Vienna
- Scheduled dates
- 25
- Classroom cities
- 24
- Classroom fee from
- 4,000 £
- Online fee from
- 2,900 £
When and where does this course run?
Showing 1–20 of 25 dates
November 2026
December 2026
January 2027
February 2027
March 2027
April 2027
May 2027
June 2027
July 2027
August 2027
Can’t find a suitable date? Tell us what you need.
What does this course cover?
Cathodic Protection Monitoring and Retrofit Design is a 1-week training course for corrosion and integrity engineers who keep buried pipelines, storage tanks and offshore structures protected, and it ends with a costed CP retrofit and monitoring plan for one asset. Ageing anode beds, coating breakdown and new stray current sources are eroding protection that was adequate when systems were commissioned. Jupiter Prime Training offers this course for engineers who inherit operating systems.
Why Cathodic Protection Monitoring and Retrofit Design Matters Now
Three forces shape cathodic protection work today. Much of the pipeline and tank inventory is past its original design life, so anodes are depleted and coatings are drawing more current than the first design assumed. High-voltage power lines, electrified rail and solar plants now share corridors with buried steel, adding interference older surveys missed. Operators that read these signals early extend asset life with targeted retrofits; those that ignore them meet leaks and unplanned excavations.
Who Gains Most from Cathodic Protection Monitoring and Retrofit Design
- Engineers responsible for pipeline protection levels and annual potential surveys
- Engineers responsible for tank bottom and terminal protection systems
- Engineers responsible for jackets, risers and subsea anode inspection findings
- Specialists responsible for transformer-rectifier performance and groundbed condition
- Integrity engineers responsible for turning protection data into repair and inspection priorities
An integrity group that sends its corrosion specialist and pipeline engineer together gains most, since both then read survey data on one basis.
Cathodic Protection Monitoring and Retrofit Design Capabilities
Participants move from reading potentials to deciding where a tired system needs new current or anodes.
- Assess remaining anode life and groundbed resistance from field records — retrofit timing decisions
- Interpret on and instant-off potential profiles and close-interval survey results — protection adequacy findings
- Test for AC and DC interference and specify mitigation bonds — neighbouring asset owners
- Calculate current demand for retrofit sacrificial and impressed current systems — capital budget holders
- Specify remote monitoring units, alarm thresholds and data trending rules — operations and control rooms
- Communicate protection status as risk-ranked integrity inputs — inspection and repair planners
Key Cathodic Protection Monitoring and Retrofit Design Terms
- Instant-off potential — the potential read just after interrupting current, free of voltage drop error.
- Close-interval survey — a walked potential survey at short spacing along a pipeline that locates poorly protected sections.
- Groundbed — the buried anode array that discharges impressed current into the soil towards the protected structure.
- Anode utilisation factor — the share of anode mass that can be consumed before the anode stops delivering useful current.
- Stray current interference — current from a foreign source that leaves a structure through the soil and corrodes it at the discharge point.
- Coupon test station — a buried steel sample wired to the structure that gives a representative off potential and current density.
Cathodic Protection Monitoring and Retrofit Design Day by Day
Day 1: Ageing Systems and Their Warning Signs
- Electrochemical Protection Principles — Setting Acceptance Criteria for Existing Assets
- Coating Breakdown and Current Demand Growth — Forecasting Retrofit Need
- Anode Depletion Records — Estimating Remaining Sacrificial System Life
- Rectifier Output Logs — Spotting Groundbed Resistance Rise Early
- Asset Records Gap Review — Deciding Which Data to Collect First
Day 2: Survey Techniques and Data Quality
- On and Instant-Off Potential Measurement — Removing Voltage Drop Error
- Close-Interval Survey Planning — Choosing Spacing and Interruption Cycles
- DCVG and ACVG Coating Defect Location — Prioritising Excavation Sites
- Coupon Test Stations — Confirming Protection Where Readings Disagree
- Reference Electrode Care and Calibration — Trusting Field Readings
Day 3: Interference and Remote Monitoring
- DC Stray Current From Rail and Foreign Systems — Agreeing Mitigation Bonds
- AC Induced Corrosion Near Power Lines — Specifying Earthing and Decoupling
- Remote Monitoring Units — Selecting Points and Reporting Frequency
- Alarm Thresholds and Trend Rules — Escalating Protection Loss Quickly
- Offshore Anode Inspection Findings — Judging Jacket and Riser Protection
Day 4: Retrofit Design Choices
- Current Requirement Calculation — Sizing Retrofit Capacity for Coated Steel
- Sacrificial Anode Retrofit Layouts — Protecting Tanks and Short Pipeline Spans
- Impressed Current Groundbed Redesign — Choosing Deep or Distributed Beds
- Tank Bottom Grid Anodes — Protecting Floors During Replacement Work
- Retrofit Option Costing — Comparing Life Extension Against Replacement
Day 5: Practising the CP Retrofit and Monitoring Plan
- Case Asset Data Review — Applying Survey and Depletion Evidence
- Interference Findings Integration — Applying Mitigation Choices to the Case
- Retrofit Sizing Exercise — Applying Current Demand Calculations
- Monitoring Point Schedule — Linking Remote Units to Integrity Risk
- CP Retrofit and Monitoring Plan — Presenting Priorities to Asset Owners
Applying Cathodic Protection Monitoring and Retrofit Design After the Course
- Rank every rectifier and anode group on one asset by remaining life and resistance trend, flagging the three most urgent.
- Re-baseline the alarm thresholds of existing remote monitoring units against recent instant-off and coupon readings.
Cathodic Protection Monitoring and Retrofit Design Questions (FAQ)
What is cathodic protection monitoring and retrofit design, and why does it matter now?
It is the practice of tracking protection levels on operating assets and redesigning systems that no longer deliver enough current. It matters now because many pipelines, tanks and platforms have outlived their first anodes while new interference sources keep appearing along shared corridors.
Which roles gain most from cathodic protection monitoring and retrofit design skills?
Corrosion and integrity engineers gain most. Pipeline, terminal and offshore engineers who own survey results, rectifier output or anode findings use the methods quickly.
How does a cathodic protection monitoring and retrofit design course differ from a new-build design course?
It starts from systems already in the ground or the sea. It reads depletion, survey and interference evidence to decide where extra current or new anodes extend life, whereas a new-build course designs from blank drawings.
What do you bring back from cathodic protection monitoring and retrofit design training?
You bring back a retrofit and monitoring plan for one real asset, with sized options, monitoring points and alarm rules.
Cathodic Protection Monitoring and Retrofit Design: The Way Forward
The CP retrofit and monitoring plan first informs which groundbeds or anode groups receive budget in the next maintenance cycle. Integrity engineers and asset owners draw on it. After the first retrofit is commissioned, the monitoring thresholds are worth revisiting, since new current distribution changes what a normal reading looks like.
Find more Petroleum Engineering & Oil and Gas Operations Courses by city
Questions about dates, fees and booking
When does this course next run?
The next session runs 23 – 27 November 2026 in Vienna. It is one of 25 dates scheduled up to October 2027.
Where is this course held?
In a classroom in 24 cities: Vienna, New York, Casablanca, Abu Dhabi, Sharm El-Sheikh, Munich, Amsterdam, Manama, and more. It is also scheduled as live online sessions.
Can I attend this course online?
Yes. One date is scheduled as a live online session: 1 – 5 August 2027, from 2,900 £ per participant.
How long is the course?
1 Week. Each date shows its start and end dates.
How much does the course cost?
Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online. Each date shows its own fee.
Is there a brochure for this course?
How do I book a place?
Choose a date above and select Register, or send us an enquiry.
Can this course be run for our team?
Yes. Tell us the number of participants and your preferred dates and city through our training request form.