Medium-Voltage Drive Upkeep and Fault Diagnosis Training Course
Power cells, cooling, control boards, fault logs and harmonic checks for electrical reliability engineers who keep large drives running.
This 1-week course has 25 dates from November 2026 to November 2027 in 24 cities and live online. The next session runs 23 – 27 November 2026 in Vienna. Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online.
See dates and book Download brochure (PDF) Training for your team
- Duration
- 1 Week
- Next start
- Vienna
- Scheduled dates
- 25
- Classroom cities
- 24
- Classroom fee from
- 4,000 £
- Online fee from
- 2,900 £
When and where does this course run?
Showing 1–20 of 25 dates
November 2026
December 2026
January 2027
February 2027
March 2027
April 2027
May 2027
June 2027
July 2027
August 2027
Can’t find a suitable date? Tell us what you need.
What does this course cover?
Medium-Voltage Drive Upkeep and Fault Diagnosis is a 1-week training course for electrical reliability engineers who look after medium-voltage variable frequency drives, ending with a drive care and fault response file for each critical unit. A tripped drive can stop a process line within seconds, and spare power modules are slow to source. The course is delivered by Jupiter Prime Training.
Why Medium-Voltage Drive Upkeep and Fault Diagnosis Matters Now
More large motors now run through variable speed drives to save energy, so the drive decides whether a pump station or compressor keeps running. Operations managers expect fast restarts after a trip, yet many sites rely on the original equipment maker for every call-out. Power quality engineers watch for harmonic distortion that a drive injects into the plant network. A site whose engineers read fault logs and test power cells shortens outages; one that cannot waits for outside help.
Who Gains Most from Medium-Voltage Drive Upkeep and Fault Diagnosis
- Engineers responsible for the reliability of drive-fed motors on pumps, fans and compressors
- Specialists who keep substations, switchrooms and drive enclosures in service
- Planners who build drive preventive maintenance routines and spares lists
- Engineers accountable for plant power quality and harmonic levels
- Commissioning engineers who hand over new drive installations to operations
An electrical maintenance section from one plant gains most when several members attend and agree a shared fault-finding sequence.
Medium-Voltage Drive Upkeep and Fault Diagnosis Capabilities
Participants trace a failed power cell, cooling fault or control board with evidence.
- Assess rectifier, DC link and inverter sections against inspection checklists — drive health status for operations
- Test cooling fans, filters, heat sinks and liquid circuits — overheating trips and enclosure upkeep
- Apply a fault code and event log diagnosis sequence — restart or escalate decisions
- Build a preventive maintenance routine per drive criticality — outage planning and spares holding
- Calculate harmonic distortion from site measurements — power quality engineers and network owners
- Specify safe isolation, discharge and earthing steps — permit issuers and electrical safety leads
Key Medium-Voltage Drive Upkeep and Fault Diagnosis Terms
- Variable frequency drive (VFD) — equipment that converts fixed supply frequency to a variable output to control motor speed and torque.
- Power cell — a modular converter unit in a cascaded drive, holding rectifier, capacitors and switching devices, replaceable as one assembly.
- DC link — the intermediate stage of capacitors or inductors that smooths rectified voltage before the inverter switches it.
- Total harmonic distortion — a measure of how far a current or voltage waveform departs from a pure sine wave.
- Bypass mode — an arrangement that lets a cell or the whole drive be bypassed so the motor keeps running after a fault.
- Fault log — the drive's stored record of trips, warnings and operating values captured around each event.
Medium-Voltage Drive Upkeep and Fault Diagnosis Day by Day
Day 1: Drive Topologies and Safe Access
- Cascaded, Neutral-Point-Clamped and Current-Source Designs — Recognising the Installed Type
- Input Transformer and Phase-Shifted Windings — Effects on Supply Quality
- Single-Line Diagram and Enclosure Layout Reading — Locating Test Points
- Isolation, Capacitor Discharge and Earthing Steps — Permit-to-Work Content
- Arc Flash Boundaries Around Drive Cabinets — Protective Equipment Selection
Day 2: Power Sections and Cooling Health
- Rectifier and Inverter Device Testing — Pass or Replace Judgements
- DC Link Capacitor Ageing Checks — Planned Replacement Timing
- Power Cell Swap and Bypass Procedure — Keeping the Motor Running
- Air Cooling Fans, Filters and Heat Sinks — Overtemperature Trip Prevention
- Liquid Cooling Circuit Conductivity and Leaks — Enclosure Integrity
Day 3: Control Boards, Protection and Fault Codes
- Control and Gate Driver Board Inspection — Board Replacement Choices
- Fibre-Optic Links and Communication Faults — Intermittent Trip Tracing
- Drive and Motor Protection Settings Review — Nuisance Trip Reduction
- Fault Code and Event Log Interpretation — Root Cause Before Reset
- Structured Fault-Finding Sequence — Restart Versus Escalation Decisions
Day 4: Harmonics, Motors and Preventive Routines
- Harmonic Measurement With Power Quality Analysers — Network Compliance Checks
- Filter and Multi-Pulse Arrangement Checks — Distortion Reduction Options
- Motor Insulation and Bearing Current Checks — Drive-Fed Motor Life
- Thermal Imaging of Drive Cabinets and Terminations — Hot Spot Priorities
- Criticality-Based Preventive Maintenance Intervals — Outage and Spares Planning
Day 5: Practising the Drive Care and Fault Response File
- Simulated Trip Diagnosis Exercise — Applying Day Three Fault Sequence
- Cooling and Power Cell Inspection Walk-Through — Applying Day Two Checks
- Harmonic Survey Results Review — Applying Day Four Measurements
- Critical Spares and Repair Turnaround Matrix — Stockholding Decisions
- Drive Care and Fault Response File — Final Version for Sign-Off
Applying Medium-Voltage Drive Upkeep and Fault Diagnosis After the Course
- Lead a cooling and power section inspection on one critical drive, logging filter, fan and capacitor condition against the checklist.
- Collect the last trips from each drive's fault log and run them through the structured fault-finding sequence to find repeat causes.
Medium-Voltage Drive Upkeep and Fault Diagnosis Questions (FAQ)
What is medium-voltage drive upkeep and fault diagnosis, and why does it matter now?
It is the routine care and structured troubleshooting of large variable frequency drives. It matters because more critical motors run through drives, and an unexplained trip can halt a process line until the cause is found.
Which roles gain most from medium-voltage drive upkeep and fault diagnosis?
Electrical reliability engineers gain most, along with switchroom specialists, maintenance planners, power quality engineers and commissioning engineers who hand drives over to operations.
How does medium-voltage drive upkeep and fault diagnosis differ from a general motors and drives course?
It concentrates on the drive cabinet itself: power cells, cooling, boards and fault logs at medium voltage. A general motors and drives course covers motor theory and low-voltage control instead.
What do you bring back from medium-voltage drive upkeep and fault diagnosis?
You bring back inspection checklists, a fault-finding sequence, harmonic check steps and a spares matrix for each critical drive.
Medium-Voltage Drive Upkeep and Fault Diagnosis: The Way Forward
The drive care and fault response file first informs whether a tripped drive is reset, bypassed or handed to specialists. Shift electricians, reliability engineers and planners use it during outages and spares reviews. After its first real trip, revisit the escalation thresholds and spares list, since restoration time shows where the file needs tightening.
Find more Maintenance, Reliability & Asset Integrity Training Courses by city
Questions about dates, fees and booking
When does this course next run?
The next session runs 23 – 27 November 2026 in Vienna. It is one of 25 dates scheduled up to November 2027.
Where is this course held?
In a classroom in 24 cities: Vienna, Madrid, Geneva, Munich, Sharm El-Sheikh, Milan, Casablanca, Barcelona, and more. It is also scheduled as live online sessions.
Can I attend this course online?
Yes. One date is scheduled as a live online session: 12 – 16 September 2027, from 2,900 £ per participant.
How long is the course?
1 Week. Each date shows its start and end dates.
How much does the course cost?
Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online. Each date shows its own fee.
Is there a brochure for this course?
How do I book a place?
Choose a date above and select Register, or send us an enquiry.
Can this course be run for our team?
Yes. Tell us the number of participants and your preferred dates and city through our training request form.