Skip to content

Steam Trap Survey, Repair and Valve Upkeep Training Course

Field surveys, failure diagnosis and valve overhaul methods for steam system and plant maintenance engineers who want dry steam and fewer losses.

This 1-week course has 25 dates from November 2026 to November 2027 in 24 cities and live online. The next session runs 22 – 26 November 2026 in Doha. Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online.

See dates and book Download brochure (PDF) Training for your team

Duration
1 Week
Next start
Doha
Scheduled dates
25
Classroom cities
24
Classroom fee from
4,000 £
Online fee from
2,900 £

When and where does this course run?

Showing 1–20 of 25 dates

November 2026

December 2026

January 2027

February 2027

March 2027

April 2027

May 2027

June 2027

July 2027

August 2027

September 2027

October 2027

Can’t find a suitable date? Tell us what you need.

What does this course cover?

Steam Trap Survey, Repair and Valve Upkeep is a 1-week training course for steam system and plant maintenance engineers who find failed traps and keep steam-line valves dependable, closing with a costed trap survey and repair schedule. Steam lost through a blowing trap or passing valve wastes fuel and erodes pipework every hour. The course is delivered by Jupiter Prime Training.

Why Steam Trap Survey, Repair and Valve Upkeep Matters Now

Energy managers must cut boiler fuel, and failed-open traps are quick losses to recover. Operations teams face water hammer, waterlogged heat exchangers and slow warm-up when condensate backs up. Asset owners want valve leakage and actuator faults caught before an unplanned isolation. A site that surveys on a routine cycle keeps steam dry and pipework intact; one that waits for visible plumes pays in fuel and corrosion.

Who Gains Most from Steam Trap Survey, Repair and Valve Upkeep

  • Engineers responsible for steam distribution mains, drip legs and tracer lines
  • Maintenance planners who schedule trap testing and valve overhaul work orders
  • Utilities engineers accountable for boiler house output and condensate return
  • Reliability engineers who track recurring trap and valve failures
  • Instrument and valve technicians who set up actuators and positioners on steam service

A utilities crew from one site gains most when several members attend and agree one survey method.

Steam Trap Survey, Repair and Valve Upkeep Capabilities

Participants judge trap condition in the field, choose repair or replacement and keep steam-line valves sealing.

  • Assess trap condition with ultrasonic, temperature and sight-glass checks — repair priority for the survey team
  • Specify the right trap type for drip, tracer and process duties — replacement purchasing decisions
  • Calculate steam loss from a failed-open trap orifice — the energy manager's budget case
  • Apply isolation and control valve inspection routines on steam lines — shutdown and overhaul planning
  • Weigh pneumatic and electric actuator options for steam valves — instrument engineering and operations
  • Design a condensate recovery check for each trap station — boiler house water and fuel targets

Key Steam Trap Survey, Repair and Valve Upkeep Terms

  • Steam trap — an automatic valve that discharges condensate and gases while holding live steam in the system.
  • Failed-open trap — a trap stuck in the discharge position, passing live steam continuously to the condensate line or atmosphere.
  • Failed-closed trap — a blocked trap that holds condensate back, causing waterlogging, cold spots and water hammer risk.
  • Flash steam — steam formed when hot condensate drops to lower pressure, often mistaken for leaking live steam.
  • Back pressure — pressure in the condensate return line that opposes trap discharge and reduces its capacity.
  • Trap station — the assembly of trap, strainer, isolation valves, test valve and check valve installed at one drain point.

Steam Trap Survey, Repair and Valve Upkeep Day by Day

Day 1: Steam Lines, Condensate and Trap Families

  • Steam Distribution and Drainage Layout — Where Drain Points Belong
  • Mechanical, Thermostatic and Thermodynamic Traps — Matching Type to Duty
  • Condensate Load Estimation — Sizing Traps for Start-Up and Running
  • Water Hammer and Air Binding Causes — Safety and Line Integrity
  • Trap Station Arrangement and Strainers — Access for Testing and Repair

Day 2: Running a Trap Survey

  • Survey Route Planning and Trap Tagging — Coverage and Repeatability
  • Ultrasonic Listening Technique — Separating Blowing, Cycling and Blocked Traps
  • Surface Temperature and Infrared Checks — Confirming Cold or Flooded Traps
  • Sight Glass and Test Valve Observation — Telling Flash From Live Steam
  • Survey Data Sheet and Condition Codes — Consistent Findings Across Crews

Day 3: Diagnosing Failures and Steam Loss

  • Failure Mode Patterns by Trap Type — Root Cause Before Replacement
  • Orifice Steam Loss Estimation — Ranking Repairs by Energy Value
  • Back Pressure and Lift Problems — Condensate Return Line Corrections
  • Repair Versus Replace Criteria — Spares Holding and Labour Use
  • Condensate Recovery and Flash Vessel Checks — Boiler Feed Water Savings

Day 4: Isolation Valves, Control Valves and Actuators

  • Gate, Globe and Ball Valves on Steam — Seat Leakage and Gland Upkeep
  • Control Valve Trim and Seat Wear — Stable Temperature Control
  • Pneumatic Versus Electric Actuators — Fail-Safe Position and Response
  • Positioner Calibration and Stroke Testing — Loop Performance Before Restart
  • Valve Repacking and Lapping Methods — Overhaul Scope at Shutdown

Day 5: Practising the Trap Survey and Repair Schedule

  • Field Survey Exercise on a Trap Line — Applying Day Two Methods
  • Loss Ranking of Surveyed Traps — Applying Day Three Estimates
  • Valve and Actuator Findings Merge — Applying Day Four Checks
  • Survey Frequency by Criticality — Setting the Retest Cycle
  • Costed Trap Survey and Repair Schedule — Final Plan for Approval

Applying Steam Trap Survey, Repair and Valve Upkeep After the Course

  • Lead a tagged ultrasonic and temperature survey of one steam main and its tracer lines, coding every trap station.
  • Rank the failed traps found by estimated steam loss and raise work orders, adding passing valves to the shutdown list.

Steam Trap Survey, Repair and Valve Upkeep Questions (FAQ)

What is steam trap survey, repair and valve upkeep, and why does it matter now?

It is the routine of testing every trap, fixing failures by priority and keeping valves sealing. It matters because failed traps waste fuel, flood heat exchangers and cause water hammer.

Which roles gain most from steam trap survey, repair and valve upkeep?

Steam distribution, utilities and maintenance planning engineers gain most, followed by reliability engineers and valve technicians who handle recurring trap failures and actuator set-up.

How does steam trap survey, repair and valve upkeep differ from a boiler operations course?

It works downstream of the boiler, on network traps, drains and valves. A boiler operations course covers firing, water chemistry and blowdown instead.

What do you bring back from steam trap survey, repair and valve upkeep?

You bring back a repeatable survey method: condition codes, steam loss estimates, valve and actuator checks and a ranked repair schedule for maintenance and energy managers.

Steam Trap Survey, Repair and Valve Upkeep: The Way Forward

The costed trap survey and repair schedule first informs which failed traps are fixed in the coming month and which valves join the next shutdown. Planners and energy managers use it to release spares. After the first survey cycle, revisit the retest frequency for critical drains, since failure rates on each line show where the cycle should tighten.

Questions about dates, fees and booking

When does this course next run?

The next session runs 22 – 26 November 2026 in Doha. It is one of 25 dates scheduled up to November 2027.

Where is this course held?

In a classroom in 24 cities: Doha, Paris, Rome, Milan, Cairo, New York, Amsterdam, Kuala Lumpur, and more. It is also scheduled as live online sessions.

Can I attend this course online?

Yes. One date is scheduled as a live online session: 30 May – 3 June 2027, from 2,900 £ per participant.

How long is the course?

1 Week. Each date shows its start and end dates.

How much does the course cost?

Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online. Each date shows its own fee.

Is there a brochure for this course?

How do I book a place?

Choose a date above and select Register, or send us an enquiry.

Can this course be run for our team?

Yes. Tell us the number of participants and your preferred dates and city through our training request form.