Skip to content

Substation Inspection and Condition-Based Maintenance Training Course

Practical inspection routes, condition monitoring and maintenance planning for substation operators, technicians and supervisors.

This 1-week course has 25 dates from November 2026 to November 2027 in 24 cities and live online. The next session runs 30 November – 4 December 2026 in Rome. Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online.

See dates and book Download brochure (PDF) Training for your team

Duration
1 Week
Scheduled dates
25
Classroom cities
24
Classroom fee from
4,000 £
Online fee from
2,900 £

What does this course cover?

Substation Inspection and Condition-Based Maintenance is a 1-week training course for substation operators, maintenance technicians and electrical supervisors, built around one named work product: a substation condition and maintenance plan. Ageing assets and leaner field crews make disciplined inspection rounds and evidence-led maintenance a priority for asset owners. Jupiter Prime Training delivers this Substation Inspection and Condition-Based Maintenance course.

Why Substation Inspection and Condition-Based Maintenance Matters Now

Two forces shape substation upkeep today. Much installed equipment is near the end of its design life, so condition rather than age must decide when it is serviced. Retiring field staff take knowledge of alarms and defects with them unless it is captured in records. A site that inspects well catches hot joints and weak battery cells before they fail; a site that inspects badly pays in forced outages and rushed repairs. The course rests on recognised condition-based maintenance practice.

Who Gains Most from Substation Inspection and Condition-Based Maintenance

  • Staff who carry out walk-round inspections in switchyards
  • Technicians who test and service transformers, circuit breakers, disconnectors, batteries and earthing
  • Shift personnel who acknowledge alarms and give the first response to substation faults
  • Supervisors who schedule maintenance work and sign off permits and job records
  • Planners who turn findings into maintenance intervals

Maintenance sections in utilities and process plants gain most when operators, technicians and their supervisor attend together.

Substation Inspection and Condition-Based Maintenance Capabilities

Participants move from noting defects to ranking equipment by condition and setting maintenance by evidence.

  • Apply structured inspection routes and checklists to every bay of a substation — consistent defect capture across shifts
  • Assess thermographic images, oil results and battery readings against alarm limits — repair-or-monitor decisions
  • Communicate alarm and fault information in a clear first report — control room and duty engineer
  • Design condition-based maintenance intervals from inspection and test history — maintenance planners and asset owners
  • Specify safe work boundaries using interlocks and permits during maintenance — supervisors issuing work
  • Build maintenance records that support trend review and audit — reliability engineers and management

Key Substation Inspection and Condition-Based Maintenance Terms

  • Condition-based maintenance — servicing equipment when measured condition shows it is needed, rather than at fixed calendar intervals.
  • Inspection round — a planned route through a substation where staff read gauges and record defects on a set sheet.
  • Infrared thermography — a thermal camera survey that finds hot spots on joints and terminations while equipment is energised.
  • Dissolved gas analysis — laboratory testing of transformer oil for gases that reveal internal overheating or arcing.
  • Health index — one score combining test results, age and defects to rank equipment.
  • Interlocking — arrangements that stop switching devices operating in an unsafe sequence.

Substation Inspection and Condition-Based Maintenance Day by Day

Day 1: Substation Layouts and Inspection Context

  • Single-Line Diagrams and Busbar Arrangements — Locating Every Bay on an Inspection Route
  • Equipment Ageing and Failure Patterns — Where Inspection Effort Pays Off Most
  • Switching Sequences and Interlocking Basics — Recognising Safe Equipment States During Rounds
  • Permit-to-Work and Safe Access Rules — Who May Approach Which Equipment
  • Maintenance Strategy Choices — Corrective, Time-Based and Condition-Based Compared

Day 2: Inspecting Primary Equipment

  • Power Transformer Visual and Gauge Checks — Oil Level, Temperature and Breather Condition
  • Circuit Breaker Operating Mechanism Inspection — Spring, Gas Pressure and Counter Readings
  • Disconnector and Earth Switch Contact Condition — Alignment, Corrosion and Operating Effort
  • Substation Battery and Charger Checks — Cell Voltage, Electrolyte and Float Current
  • Earthing Grid and Connection Inspection — Theft, Corrosion and Continuity Concerns

Day 3: Condition Monitoring Methods

  • Infrared Thermography Surveys — Grading Hot Spots by Temperature Rise
  • Transformer Oil Sampling and Dissolved Gas Results — Internal Fault Warning Signs
  • Partial Discharge and Acoustic Detection — Insulation Deterioration in Switchgear and Cables
  • Circuit Breaker Timing and Contact Resistance Trends — Mechanism and Contact Wear
  • Equipment Health Index Scoring — Ranking Assets for Intervention

Day 4: Alarm Handling, Fault Response and Planning

  • Alarm Annunciator and Control Panel Indications — Separating Urgent From Routine Alarms
  • First Response to Tripping and Protection Operation — Information the Control Room Needs
  • Post-Fault Equipment Checks — Deciding Whether Plant Can Be Restored
  • Condition-Based Interval Setting — Moving Tasks From Calendar to Evidence
  • Maintenance Work Order and Spares Planning — Matching Crews, Outages and Materials

Day 5: Practising the Substation Condition and Maintenance Plan

  • Inspection Route and Checklist Build — Applying Layout and Equipment Checks
  • Condition Findings Ranking Exercise — Applying Thermography, Oil and Battery Results
  • Fault Scenario Walk-Through — Applying Alarm Handling and First Response
  • Maintenance Record Structure — Capturing History for Trend Review and Audit
  • Substation Condition and Maintenance Plan — Completing and Presenting the Work Product

Applying Substation Inspection and Condition-Based Maintenance After the Course

  • Run a revised inspection round on one substation with the bay-by-bay checklist and compare defects with the previous log.
  • Review one year of transformer, breaker and battery records, score each asset with a health index and propose new condition-based intervals.

Substation Inspection and Condition-Based Maintenance Questions (FAQ)

What is substation inspection and condition-based maintenance, and why does it matter now?

It is the practice of inspecting substation equipment on set routes and planning maintenance from measured condition. It matters now because ageing equipment and outage pressure leave little room for missed defects.

Which roles gain most from substation inspection and condition-based maintenance?

Substation operators, maintenance technicians and electrical supervisors gain most. Each gains a shared basis for rounds, test results and maintenance planning.

How does substation inspection and condition-based maintenance differ from a high-voltage switching course?

A switching course concentrates on isolation and switching authorisation. This course covers the whole substation: inspection rounds, condition monitoring, alarm and fault response, maintenance planning and records.

What do you bring back from substation inspection and condition-based maintenance training?

You bring back a substation condition and maintenance plan for a site of your choice. It holds an inspection route, a condition ranking of equipment, revised intervals and a record structure.

Substation Inspection and Condition-Based Maintenance: The Way Forward

The substation condition and maintenance plan first informs which equipment receives attention in the next outage window. Supervisors and planners use it to allocate crews and spares. After its first cycle, revisit the alarm limits and chosen intervals against what the inspections actually found, so operators on every shift follow a route that reflects real equipment condition.

When and where does this course run?

Showing 1–20 of 25 dates

November 2026

December 2026

January 2027

February 2027

March 2027

April 2027

May 2027

June 2027

July 2027

August 2027

September 2027

October 2027

Can’t find a suitable date? Tell us what you need.

Questions about dates, fees and booking

When does this course next run?

The next session runs 30 November – 4 December 2026 in Rome. It is one of 25 dates scheduled up to November 2027.

Where is this course held?

In a classroom in 24 cities: Rome, Dubai, Milan, Singapore, Istanbul, Madrid, Doha, Kuala Lumpur, and more. It is also scheduled as live online sessions.

Can I attend this course online?

Yes. One date is scheduled as a live online session: 3 – 7 January 2027, from 2,900 £ per participant.

How long is the course?

1 Week. Each date shows its start and end dates.

How much does the course cost?

Fees per participant run from 4,000 £ (Cairo) to 9,500 £ (New York) in a classroom, and from 2,900 £ live online. Each date shows its own fee.

Is there a brochure for this course?

How do I book a place?

Choose a date above and select Register, or send us an enquiry.

Can this course be run for our team?

Yes. Tell us the number of participants and your preferred dates and city through our training request form.

More ways to train